Automatic Capacitor Banks
With Harmonic Rejection Filters

With Filters to the 5th Harmonic

5th harmonic filters, tuned to 189 Hz

Equipment designed to work in 400V networks and with a high harmonic level. With capacitors reinforced in voltage of 480V nominal and withstand 525V up to 8 hours a day. Incorporates harmonic rejection filters tuned to 189 Hz, based on three-phase inductance and designed to reject harmonics of order 5º and higher. IP 31 enclosure with ventilation grille and forced ventilation with thermostats. It incorporates a standard autotransformer with 230V output for the control circuit. Capable of withstanding up to 6% THDu.

With 3rd Harmonic Filters

3rd harmonic filters, tuned to 134 Hz

Equipment designed to work in 400V networks and with a high harmonic level. With capacitors reinforced in voltage of 480V nominal and withstand 525V up to 8 hours a day. Incorporates harmonic rejection filters tuned to 134 Hz, based on three-phase inductance and designed to reject harmonics of 3rd order and higher. IP 31 enclosure with ventilation grille and forced ventilation with thermostats. It incorporates a standard autotransformer with 230V output for the control circuit. Capable of withstanding up to 8% THDu.

Statics with 5th Harmonic Filters

Filters 5th harmonics, tuned to 189 Hz | Thyristor control

Equipment designed to work in 400V networks and with a high harmonic level. With capacitors reinforced in voltage of 480V nominal and withstand 525V up to 8 hours a day. It incorporates harmonic rejection filters tuned to 189 Hz, based on three-phase inductances and designed to reject harmonics of order 5º and higher. The maneuver is executed by thyristors. IP 31 enclosure with ventilation grille and forced ventilation with thermostats. It incorporates a standard autotransformer with 230V output for the control circuit. Capable of withstanding up to 6% THDu.

Related Articles

No post found!

Request a Quote

    Scroll to Top
    Contact us